{"product_id":"parr-6200-isoperibol-oxygen-bomb-calorimeter-with-6510-water-handling-system","title":"Parr 6200 Isoperibol Oxygen Bomb Calorimeter with 6510 Water Handling System","description":"\u003cfont rwr=\"1\" style=\"\"\u003e\n \u003cp style=\"font-family: Arial; font-size: 14pt;\"\u003e\n \u003c\/p\u003e\n \u003cp align=\"center\" style=\"font-family: Arial; font-size: 14pt;\"\u003e\n  \u003cfont face=\"Arial\" size=\"2\"\u003e\n   \u003cfont size=\"2\"\u003e\n    \u003cfont color=\"#ff0010\" face=\"Arial\" size=\"6\"\u003e\n     \u003cem\u003e\n     \u003c\/em\u003e\n    \u003c\/font\u003e\n   \u003c\/font\u003e\n  \u003c\/font\u003e\n \u003c\/p\u003e\n \u003cdiv align=\"center\" style=\"font-family: Arial; font-size: 14pt;\"\u003e\n  \u003cbr\u003e\n \u003c\/div\u003e\n \u003cdiv align=\"center\" style=\"font-family: Arial; font-size: 14pt;\"\u003e\n  \u003cimg src=\"https:\/\/lh3.googleusercontent.com\/3ORmjpZZm9ptg52IzbV80Mfr-Dgkuv2GIFAv0K3hs_wOa6c4qtwq4IbulK4bidMlBm6fK_cs1OArLS5JfXYJTU5pLPb6zmZ4ld9--Q09ccZebNGtUkvIgfXMQ4qwqIuvto1M661e5sIvAJVWmjUNcb8f7-QdZ3GAxJuB9jTy13azXl1m-rVn9XrfJf0scIlhggwtX6X0tQK9zYXNhdfMCiud2gNyp3mQm0W8AqUo5NI66Dtp81zT2t15bGfb5c8YZI_GsGk8C8kOni1uG9XQytUHkEZNj18kN1wEAbrt8iK7w-taLYAPm6htt-iVaqdzXbaYY_zk0_JZWdE1Gk6JOU95YYVxQbqs330NhhwLTZWVN9iIB-tnaEZTPxwiIUDtwo1LRH9fVXE7uaAVzab0pEzV5ORyUk88yszlLaRF40qEzZcFjByfB6KszBHFa2OVmTCU6gnIMye9y8q2-D-RBM43XKE548ECmcZd6wvNtAxngPGbhbkd5_8vKXLrSc8LKfg-v3FpT_H_vy2xxAOIoqNuLjLMFVZp4pEYfW8A78ybS4EABThQPbNlpBn8a2wKJU4Z9_Mec9cOvF4R544Biy_cWi9yr1b65uBR8Nsdm1-FWmqsvXOoYF7w9YKN2LGqzACUooXDULvpjsbjT0wtsJ8IzjV47_p_ETW8ZFNCvOTWLF0DV0PNBHI=w600-h188-no\"\u003e\n \u003c\/div\u003e\n \u003cdiv align=\"center\" style=\"font-family: Arial; font-size: 14pt;\"\u003e\n  \u003cbr\u003e\n \u003c\/div\u003e\n \u003cdiv align=\"center\" style=\"font-family: Arial; font-size: 14pt;\"\u003e\n  \u003cbr\u003e\n \u003c\/div\u003e\n \u003cdiv align=\"center\" style=\"\"\u003e\n  \u003cfont color=\"#0080bc\" face=\"Arial\" size=\"6\"\u003e\n   \u003cb\u003e\n    \u003ci\u003e\n     Parr 6200 Isoperibol Oxygen Bomb Calorimeter\n    \u003c\/i\u003e\n   \u003c\/b\u003e\n  \u003c\/font\u003e\n \u003c\/div\u003e\n \u003cdiv align=\"center\" style=\"\"\u003e\n  \u003cfont color=\"#0080bc\" face=\"Arial\" size=\"6\"\u003e\n   \u003cb\u003e\n    \u003ci\u003e\n     with 6510 Water Handling System\n    \u003c\/i\u003e\n   \u003c\/b\u003e\n  \u003c\/font\u003e\n \u003c\/div\u003e\n \u003cdiv align=\"center\" style=\"font-family: Arial; font-size: 14pt;\"\u003e\n  \u003cspan style=\"font-size: x-large;\"\u003e\n   \u003cbr\u003e\n  \u003c\/span\u003e\n \u003c\/div\u003e\n \u003cdiv align=\"center\" style=\"font-family: Arial; font-size: 14pt;\"\u003e\n  \u003cspan style=\"font-size: x-large;\"\u003e\n   ITEM INFORMATION\n  \u003c\/span\u003e\n \u003c\/div\u003e\n \u003cdiv align=\"center\" style=\"font-family: Arial; font-size: 14pt;\"\u003e\n  \u003cspan style=\"font-size: x-large;\"\u003e\n   \u003cbr\u003e\n  \u003c\/span\u003e\n \u003c\/div\u003e\n \u003cbr\u003e\n \u003cfont face=\"Arial\" size=\"2\" style=\"font-family: Arial; font-size: 14pt;\"\u003e\n  \u003ctable align=\"center\" border=\"1\" cellpadding=\"1\" cellspacing=\"1\" width=\"75%\"\u003e\n   \u003ctbody\u003e\n    \u003ctr\u003e\n     \u003ctd width=\"26%\"\u003e\n      \u003cfont face=\"Arial\" size=\"+1\"\u003e\n       ITEM:\n      \u003c\/font\u003e\n     \u003c\/td\u003e\n     \u003ctd width=\"74%\"\u003e\n      \u003cfont size=\"4\"\u003e\n       Isoperibol Oxygen Calorimeter\n      \u003c\/font\u003e\n     \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n     \u003ctd\u003e\n      \u003cfont face=\"Arial\" size=\"+1\"\u003e\n       MAKE:\n      \u003c\/font\u003e\n     \u003c\/td\u003e\n     \u003ctd\u003e\n      \u003cfont size=\"4\"\u003e\n       Parr\n      \u003c\/font\u003e\n     \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n     \u003ctd\u003e\n      \u003cfont face=\"Arial\" size=\"+1\"\u003e\n       MODEL:\n      \u003c\/font\u003e\n     \u003c\/td\u003e\n     \u003ctd\u003e\n      \u003cfont size=\"4\"\u003e\n       6200 and 6510\n      \u003c\/font\u003e\n     \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n     \u003ctd\u003e\n      \u003cfont face=\"Arial\" size=\"+1\"\u003e\n       NEW\/USED:\n      \u003c\/font\u003e\n     \u003c\/td\u003e\n     \u003ctd\u003e\n      \u003cfont size=\"4\"\u003e\n       USED\n      \u003c\/font\u003e\n     \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n     \u003ctd\u003e\n      \u003cfont face=\"Arial\" size=\"+1\"\u003e\n       FUNCTIONALITY:\n      \u003c\/font\u003e\n     \u003c\/td\u003e\n     \u003ctd\u003e\n      \u003cfont size=\"4\"\u003e\n       USED - 30 DAY WARRANTY\n      \u003c\/font\u003e\n     \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n     \u003ctd\u003e\n      \u003cfont face=\"Arial\" size=\"+1\"\u003e\n       COSMETIC:\n      \u003c\/font\u003e\n     \u003c\/td\u003e\n     \u003ctd\u003e\n      \u003cfont size=\"4\"\u003e\n       SEE PHOTOS - NOTE CRACK IN CASE - DETAILED PHOTO\n      \u003c\/font\u003e\n     \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n     \u003ctd\u003e\n      \u003cfont size=\"4\"\u003e\n       ACCESSORIES:\n      \u003c\/font\u003e\n     \u003c\/td\u003e\n     \u003ctd\u003e\n      \u003cfont size=\"4\"\u003e\n       NONE - SEE PHOTOS\n      \u003c\/font\u003e\n     \u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n     \u003ctd\u003e\n      \u003cfont face=\"Arial\" size=\"+1\"\u003e\n       ITEM NUMBER:\n      \u003c\/font\u003e\n     \u003c\/td\u003e\n     \u003ctd\u003e\n      \u003cfont size=\"4\"\u003e\n       R4F - 6200-1706-73827, M55382, 092018\n      \u003c\/font\u003e\n     \u003c\/td\u003e\n    \u003c\/tr\u003e\n   \u003c\/tbody\u003e\n  \u003c\/table\u003e\n \u003c\/font\u003e\n \u003cp style=\"font-family: Arial; font-size: 14pt; box-sizing: border-box; padding: 0px 0px 15px; margin: 0px 0px 10px; border: 0px; font-variant-numeric: inherit; font-variant-east-asian: inherit; font-stretch: inherit; line-height: inherit; vertical-align: baseline; color: rgb(20, 20, 20); background-color: rgb(255, 255, 255);\"\u003e\n  \u003cspan style=\"color: rgb(0, 0, 0); font-size: 18.6667px;\"\u003e\n   \u003cbr\u003e\n  \u003c\/span\u003e\n \u003c\/p\u003e\n \u003cp style=\"font-family: Arial; font-size: 14pt; box-sizing: border-box; padding: 0px 0px 15px; margin: 0px 0px 10px; border: 0px; font-variant-numeric: inherit; font-variant-east-asian: inherit; font-stretch: inherit; line-height: inherit; vertical-align: baseline; color: rgb(20, 20, 20); background-color: rgb(255, 255, 255);\"\u003e\n  \u003cspan style=\"color: rgb(0, 0, 0); font-size: 18.6667px;\"\u003e\n   This item will be shipped via motor freight.  The shipping price includes delivery to a business with unloading capabilities or to the nearest terminal only!  Residential, office, university, or other limited access delivery is an additional $150, this includes home offices.\n  \u003c\/span\u003e\n \u003c\/p\u003e\n \u003cp style=\"font-family: Arial; font-size: 14pt; box-sizing: border-box; padding: 0px 0px 15px; margin: 0px 0px 10px; border: 0px; font-variant-numeric: inherit; font-variant-east-asian: inherit; font-stretch: inherit; line-height: inherit; vertical-align: baseline; color: rgb(20, 20, 20); background-color: rgb(255, 255, 255);\"\u003e\n  \u003cspan style=\"color: rgb(0, 0, 0); font-size: 18.6667px;\"\u003e\n   \u003cbr\u003e\n  \u003c\/span\u003e\n \u003c\/p\u003e\n \u003cp style=\"box-sizing: inherit; margin-bottom: 1.5em; color: rgb(64, 64, 64);\"\u003e\n  \u003cfont face=\"Arial\" size=\"4\" style=\"\"\u003e\n   \u003cspan style=\"box-sizing: inherit; font-weight: 600;\"\u003e\n    Model 6200 is a microprocessor controlled, isoperibol oxygen bomb calorimeter\n   \u003c\/span\u003e\n   which is widely used for both routine and occasional calorific tests. It uses the time-tested Parr 1108 style oxygen bomb and oval bucket in a compact calorimeter, producing reliable results with good repeatability, but differing from the 6400 Model in that the bomb and bucket both must be removed from the calorimeter and refilled manually for each test, thereby requiring more of the operator's time than the 6400 model.\n  \u003c\/font\u003e\n \u003c\/p\u003e\n \u003cp style=\"box-sizing: inherit; margin-bottom: 1.5em; color: rgb(64, 64, 64);\"\u003e\n  \u003cfont face=\"Arial\" size=\"4\"\u003e\n   All sensors, controls and jacketing in the 6200 Calorimeter are built into a single, compact cabinet to provide a self-contained operating unit consisting of:\n  \u003c\/font\u003e\n \u003c\/p\u003e\n \u003cul style=\"box-sizing: inherit; margin: 0px 0px 1.5em 3em; list-style-position: initial; list-style-image: initial; color: rgb(64, 64, 64);\"\u003e\n  \u003cli style=\"box-sizing: inherit;\"\u003e\n   \u003cfont face=\"Arial\" size=\"4\"\u003e\n    A temperature-controlled water jacket with a built-in circulating system and an electric heater.\n   \u003c\/font\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"box-sizing: inherit;\"\u003e\n   \u003cfont face=\"Arial\" size=\"4\"\u003e\n    An 1108P oxygen bomb with an oval bucket which fits into the insulating water jacket.\n   \u003c\/font\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"box-sizing: inherit;\"\u003e\n   \u003cfont face=\"Arial\" size=\"4\"\u003e\n    A built-in automatic system for charging the bomb with oxygen.\n   \u003c\/font\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"box-sizing: inherit;\"\u003e\n   \u003cfont face=\"Arial\" size=\"4\"\u003e\n    A high precision electronic thermometer.\n   \u003c\/font\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"box-sizing: inherit;\"\u003e\n   \u003cfont face=\"Arial\" size=\"4\"\u003e\n    A bright, color, touch screen display for data entry and operation control.\n   \u003c\/font\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"box-sizing: inherit;\"\u003e\n   \u003cfont face=\"Arial\" size=\"4\"\u003e\n    Special communication ports for printer, computer and network (LAN) connections.\n   \u003c\/font\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"box-sizing: inherit;\"\u003e\n   \u003cfont face=\"Arial\" size=\"4\"\u003e\n    SD memory card slots for simple program updates and test report archiving.\n   \u003c\/font\u003e\n  \u003c\/li\u003e\n \u003c\/ul\u003e\n \u003cp style=\"box-sizing: inherit; margin-bottom: 1.5em; color: rgb(64, 64, 64);\"\u003e\n  \u003cfont face=\"Arial\" size=\"4\"\u003e\n   A variety of vessels are available for testing samples releasing from 52 calories to 12,000 calories per test.\n  \u003c\/font\u003e\n \u003c\/p\u003e\n \u003ch4 style=\"box-sizing: inherit; color: rgb(64, 64, 64);\"\u003e\n  \u003cfont face=\"Arial\" size=\"4\"\u003e\n   Precise Electronic Thermometry\n  \u003c\/font\u003e\n \u003c\/h4\u003e\n \u003cp style=\"box-sizing: inherit; margin-bottom: 1.5em; color: rgb(64, 64, 64);\"\u003e\n  \u003cfont face=\"Arial\" size=\"4\"\u003e\n   Temperatures are measured with a high precision electronic thermometer using a specially designed thermistor sensor sealed in a stainless steel probe which is fixed in the calorimeter cover. Measurements are taken with 0.0001° resolution over a 20° to 40°C working range, with all readings shown in Celsius.\n  \u003c\/font\u003e\n \u003c\/p\u003e\n \u003ch4 style=\"box-sizing: inherit; color: rgb(64, 64, 64);\"\u003e\n  \u003cfont face=\"Arial\" size=\"4\"\u003e\n   Effective Thermal Jacketing\n  \u003c\/font\u003e\n \u003c\/h4\u003e\n \u003cp style=\"box-sizing: inherit; margin-bottom: 1.5em; color: rgb(64, 64, 64);\"\u003e\n  \u003cfont face=\"Arial\" size=\"4\"\u003e\n   Outstanding thermal jacketing is provided by a circulating water system driven by a built-in, high capacity pump which maintains a continuous forced flow around the sides and bottom of the bucket chamber and through the cover as well. The jacket temperature is held constant for isoperibol operation and no water additions or waiting periods are required at the end of a run. A sealed immersion heater and a built-in heat exchanger, both operated by the calorimeter controller, provide precise jacket temperature control.\n  \u003c\/font\u003e\n \u003c\/p\u003e\n \u003ch4 style=\"box-sizing: inherit; color: rgb(64, 64, 64);\"\u003e\n  \u003cfont face=\"Arial\" size=\"4\"\u003e\n   A Reliable Oxygen Bomb\n  \u003c\/font\u003e\n \u003c\/h4\u003e\n \u003cp style=\"box-sizing: inherit; margin-bottom: 1.5em; color: rgb(64, 64, 64);\"\u003e\n  \u003cfont face=\"Arial\" size=\"4\"\u003e\n   The Parr 1108P Oxygen Bomb furnished with the calorimeter will safely burn samples liberating up to 8000 calories per charge, using oxygen charging pressures up to 40 atm. An alternate 1108PCL bomb with superior resistance to chlorine and halogen acids is recommended for tests involving waste material and chlorinated samples.\n  \u003c\/font\u003e\n \u003c\/p\u003e\n \u003ch4 style=\"box-sizing: inherit; color: rgb(64, 64, 64);\"\u003e\n  \u003cfont face=\"Arial\" size=\"4\"\u003e\n   A Built-In Oxygen Filling System\n  \u003c\/font\u003e\n \u003c\/h4\u003e\n \u003cp style=\"box-sizing: inherit; margin-bottom: 1.5em; color: rgb(64, 64, 64);\"\u003e\n  \u003cfont face=\"Arial\" size=\"4\"\u003e\n   To speed and simplify the bomb filling operation, the 6200 Calorimeter has an automatic system for charging the bomb with oxygen. Oxygen from a commercial cylinder is connected to a microprocessor controlled solenoid installed in the calorimeter. To fill the bomb, the operator simply slips the filling hose connector onto the bomb inlet valve and pushes the touch screen to start the filling sequence. Filling then proceeds automatically at a controlled rate to a pre-set pressure.\n  \u003c\/font\u003e\n \u003c\/p\u003e\n \u003ch4 style=\"box-sizing: inherit; color: rgb(64, 64, 64);\"\u003e\n  \u003cfont face=\"Arial\" size=\"4\"\u003e\n   Automatic Standardization\n  \u003c\/font\u003e\n \u003c\/h4\u003e\n \u003cp style=\"box-sizing: inherit; margin-bottom: 1.5em; color: rgb(64, 64, 64);\"\u003e\n  \u003cfont face=\"Arial\" size=\"4\"\u003e\n   The 6200 Calorimeter will automatically generate its energy equivalent (EE) value from a series of standardization tests, calculating a mean value from an operator defined number of the last standardization tests for each bomb\/ bucket combination. The default number of tests is 10 as specified by ASTM and international methods. The user can enter the maximum standard deviation he will accept and the calorimeter will advise him if his tests fail to meet this criteria. Energy equivalent values for up to four bomb\/bucket combinations can be stored in the computer.\n  \u003c\/font\u003e\n \u003c\/p\u003e\n \u003ch4 style=\"box-sizing: inherit; color: rgb(64, 64, 64);\"\u003e\n  \u003cfont face=\"Arial\" size=\"4\"\u003e\n   Many User Options\n  \u003c\/font\u003e\n \u003c\/h4\u003e\n \u003cp style=\"box-sizing: inherit; margin-bottom: 1.5em; color: rgb(64, 64, 64);\"\u003e\n  \u003cfont face=\"Arial\" size=\"4\"\u003e\n   Although specific procedures are recommended, various options are available to the user:\n  \u003c\/font\u003e\n \u003c\/p\u003e\n \u003cul style=\"box-sizing: inherit; margin: 0px 0px 1.5em 3em; list-style-position: initial; list-style-image: initial; color: rgb(64, 64, 64);\"\u003e\n  \u003cli style=\"box-sizing: inherit;\"\u003e\n   \u003cfont face=\"Arial\" size=\"4\"\u003e\n    Program parameters can be adjusted to accommodate unusual sample sizes and precision requirements.\n   \u003c\/font\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"box-sizing: inherit;\"\u003e\n   \u003cfont face=\"Arial\" size=\"4\"\u003e\n    The calorimeter can be programmed to accommodate any titrant concentrations selected by the user.\n   \u003c\/font\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"box-sizing: inherit;\"\u003e\n   \u003cfont face=\"Arial\" size=\"4\"\u003e\n    Calorific values can be reported in any of several measurement units.\n   \u003c\/font\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"box-sizing: inherit;\"\u003e\n   \u003cfont face=\"Arial\" size=\"4\"\u003e\n    The calorimeter program can be adjusted to compensate for the subtle differences in the way acid correction values are handled in ASTM, BS, DIN and ISO methods.\n   \u003c\/font\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"box-sizing: inherit;\"\u003e\n   \u003cfont face=\"Arial\" size=\"4\"\u003e\n    Program controls can be protected from inadvertent changes.\n   \u003c\/font\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"box-sizing: inherit;\"\u003e\n   \u003cfont face=\"Arial\" size=\"4\"\u003e\n    A bomb usage tally can be maintained to notify the user when each bomb should be serviced.\n   \u003c\/font\u003e\n  \u003c\/li\u003e\n \u003c\/ul\u003e\n \u003ch4 style=\"box-sizing: inherit; color: rgb(64, 64, 64);\"\u003e\n  \u003cfont face=\"Arial\" size=\"4\"\u003e\n   Multiple Language Options\n  \u003c\/font\u003e\n \u003c\/h4\u003e\n \u003cp style=\"box-sizing: inherit; margin-bottom: 1.5em; color: rgb(64, 64, 64);\"\u003e\n  \u003cfont face=\"Arial\" size=\"4\"\u003e\n   Parr Model 6200 can be set to provide the programming options, operating menus, reports and error messages in the following choice of languages: English, French, German, Spanish, Italian, Polish, Chinese, Russian and Czech.\n  \u003c\/font\u003e\n \u003c\/p\u003e\n \u003ch4 style=\"box-sizing: inherit; color: rgb(64, 64, 64);\"\u003e\n  \u003cfont face=\"Arial\" size=\"4\"\u003e\n   Automatic Data Transfer\n  \u003c\/font\u003e\n \u003c\/h4\u003e\n \u003cp style=\"box-sizing: inherit; margin-bottom: 1.5em; color: rgb(64, 64, 64);\"\u003e\n  \u003cfont face=\"Arial\" size=\"4\"\u003e\n   The calorimeter is equipped with a USB port for reporting to a printer and receiving sample weights from an analytical balance. Transferring results to a laboratory computer is accomplished using an Ethernet connection using standard network protocols.\n  \u003c\/font\u003e\n \u003c\/p\u003e\n \u003ch4 style=\"box-sizing: inherit; color: rgb(64, 64, 64);\"\u003e\n  \u003cfont face=\"Arial\" size=\"4\"\u003e\n   Compatible Modular Design\n  \u003c\/font\u003e\n \u003c\/h4\u003e\n \u003cp style=\"box-sizing: inherit; margin-bottom: 1.5em; color: rgb(64, 64, 64);\"\u003e\n  \u003cfont face=\"Arial\" size=\"4\"\u003e\n   The 6200 Calorimeter is fully compatible with existing 1108 Parr Bombs and closed-circuit water handling systems (see our other listings for closed-circuit water handling system) making it easy to fit the instrument into an existing laboratory set-up.  A modular design, with the controller electronics assembled in a removable chassis, simplifies maintenance.\n  \u003c\/font\u003e\n \u003c\/p\u003e\n \u003cul style=\"box-sizing: inherit; margin: 0px 0px 1.5em 3em; list-style-position: initial; list-style-image: initial; color: rgb(64, 64, 64);\"\u003e\n  \u003cli style=\"box-sizing: inherit;\"\u003e\n   \u003cfont face=\"Arial\" size=\"4\"\u003e\n    Isoperibol calorimetry\n   \u003c\/font\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"box-sizing: inherit;\"\u003e\n   \u003cfont face=\"Arial\" size=\"4\"\u003e\n    Removable Bucket\n   \u003c\/font\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"box-sizing: inherit;\"\u003e\n   \u003cfont face=\"Arial\" size=\"4\"\u003e\n    4-7 tests per hour\n   \u003c\/font\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"box-sizing: inherit;\"\u003e\n   \u003cfont face=\"Arial\" size=\"4\"\u003e\n    Operator time per test is approximately 6 minutes\n   \u003c\/font\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"box-sizing: inherit;\"\u003e\n   \u003cfont face=\"Arial\" size=\"4\"\u003e\n    0.05 - 0.1% precision class instrument\n   \u003c\/font\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"box-sizing: inherit;\"\u003e\n   \u003cfont face=\"Arial\" size=\"4\"\u003e\n    0.0001 ºC Temperature Resolution\n   \u003c\/font\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"box-sizing: inherit;\"\u003e\n   \u003cfont face=\"Arial\" size=\"4\"\u003e\n    52 - 12000 calorie sample range dependent on vessel selected\n   \u003c\/font\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"box-sizing: inherit;\"\u003e\n   \u003cfont face=\"Arial\" size=\"4\"\u003e\n    0.05% Linearity across operating range\n   \u003c\/font\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"box-sizing: inherit;\"\u003e\n   \u003cfont face=\"Arial\" size=\"4\"\u003e\n    SD memory and TCP\/IP network communications\n   \u003c\/font\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"box-sizing: inherit;\"\u003e\n   \u003cfont face=\"Arial\" size=\"4\"\u003e\n    USB Port for balance and printer connections\n   \u003c\/font\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"box-sizing: inherit;\"\u003e\n   \u003cfont face=\"Arial\" size=\"4\"\u003e\n    Updates via the Internet\n   \u003c\/font\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"box-sizing: inherit;\"\u003e\n   \u003cfont face=\"Arial\" size=\"4\"\u003e\n    Dimensions (in) 23w x 16d x 17h\n   \u003c\/font\u003e\n  \u003c\/li\u003e\n  \u003cli style=\"box-sizing: inherit;\"\u003e\n   \u003cfont face=\"Arial\" style=\"\"\u003e\n    \u003cfont size=\"4\"\u003e\n     Dimensions (cm) 57w x 40d x 4\n    \u003c\/font\u003e\n    3h\n   \u003c\/font\u003e\n  \u003c\/li\u003e\n \u003c\/ul\u003e\n \u003cp style=\"font-family: Arial; font-size: 14pt;\"\u003e\n \u003c\/p\u003e\n \u003cp align=\"center\" style=\"font-family: Arial; font-size: 14pt; text-align: left;\"\u003e\n \u003c\/p\u003e\n\u003c\/font\u003e\n","brand":"Parr","offers":[{"title":"Default Title","offer_id":42985731260510,"sku":null,"price":24998.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0667\/1905\/5966\/files\/10_21a5c1ca-cf20-4bc2-9419-3c3356bdee91.png?v=1783543859","url":"https:\/\/totalasset.net\/products\/parr-6200-isoperibol-oxygen-bomb-calorimeter-with-6510-water-handling-system","provider":"Total Asset Solutions","version":"1.0","type":"link"}